Call

METHODS

Our METHODS

Application of the most appropriate method * and a thorough understanding of the characteristics and geometry of a particular tank is absolutely essential. Here is where long years of experience, engineering, and mathematical background are indispensable.

A combination of traditional strapping and physical calibration with the latest laser distance ranging and optical triangulation technology may be required to acquire all the necessary field data of any tank. Every tank may require different methods and approaches to achieve accurate data. *

In India, we follow rules laid down by the Directorate of Legal Metrology (click here to go to website) (Weights & Measures department) for vertical cyl. tanks for petroleum products - also called the "strapping method":

Internationally, and for any tank being approved by CPWD in India, we may also follow BIS 2007, BIS 2009, BIS 2166, and international standards like ISO 7507 - part 1 to 4, ISO 12917, API (American Petroleum Institute) 2550, API 2551, API 2552, API MPMS 2.8.A, from which the national standards and rules are derived. The ISO rules have also been recommended by OIML (International Organization of Legal Metrology - click here to download PDF) , of which every country, including India, is a member.

An internal survey is carried out in tanks where it is safe to enter, enabling us to measure datum plates, internal deadwood & tank bottom floor/shape. Underground horizontal tanks require internal measurements. Bottom plate unevenness is profiled, and physical calibration with water is done up to flush point as required. Safe Laser beam measurements are also used for internal measurements for horton spheres and underground cylindrical tanks.

All field data are fed into our computer with customized software for specific corrections like tape temperature corrections, thickness corrections, deadwood corrections, etc., and shell-wise calculations as per International ISO methods and Rules laid down by the Weights and Measures Dept. Complex mathematical integration, formulae, and calculations are involved in the case of horizontal tanks where ends are torispherical, and the tank is tilted, as the volume increment is non-linear.

Calibration charts are made in SI or British units as per requirement. In India, for spirit tanks in distilleries/breweries under excise, gauging tables are also computed as per excise rules. Calibration charts can also be given in weight. Tank calibration data can be provided on softcopy data for uploading to inventory monitoring software.

Horizontal / Spherical Tanks

International method: ISO 12917 - part 1, API 2551. BIS: IS-2009. Internal Dia. (vertical & horizontal) of all shells, length of horizontal tanks, datum plate height. Inclination & spherical dish-end measurements of horizontal tanks. Calibration of Horton Spheres (API 2552 method) and horizontal bullets: determination of internal vertical & horizontal diameters, position of auto gauge with respect to tank floor. Accurate Distance Lasers with maximum/minimum length and slope determination can be used.

Liquid Cargo Ship Tanks

The International API MPMS 2.8A method is followed. Measurements are taken for deadwoods, corrugated bulkheads, deadrises, bilge radii, etc. Correction for trim, list, and temperature is done.

On-site Physical Calibration

For uneven, inclined tank floors, spherical or conical bottoms, determination of the flush point of the bottom of tanks is done by measuring water through a flow meter or prover. Floatation of the roof of floating roof tanks by water is done to determine volume displacement by the weight of the roof. This displacement is to be applied for density corrections of liquid stored. Wet calibration at intervals is required for deformed, inclined horizontal tanks or irregularly bulging rectangular tanks.

Tank Settlement Survey

API 653-B method is followed. Out-of-roundness, tank tilt, and settlement survey.

Methods at a Glance

Vendor Codes

IOC: 11931311    BPCL: 148016    HPCL: 28089118    RIL: 321170

Thorough understanding of tank geometry. Highest accuracy in measurements. Computerized mathematical calculations and advanced computations. Error-free SAP/ERP software compatible. Lowest on-site and off-site execution time. Production hold-ups minimized. Cuts your losses

Methods for calibration may vary as per rules and regulations in force in the particular state or country. Currently, we have repairer licenses of the Dir. of Legal Metrology in various states (Please enquire for approvals). It is to be noted that in India, the Legal Metrology Dept. of the state carries out the stamping of tanks, and we assist the Inspector. Govt. Stamping fees is liable to be paid by the owner of the tank to the Dir. of Legal Metrology as per prescribed rules in every state.